Part Image

AH05P-12 - XP POWER

Description: Isolated DC/DC Converters SINGLE O/P, DC-HV DC PCB MOUNT, 1.5W, +500V

Download AH05P-12 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
AH05P-12 - XP POWER PCB footprint - Other - Other - AH05P-12-1
click to zoom
3D Models
AH05P-12 - XP POWER  - 3D model - Other - AH05P-12-1
click to zoom

AH05P-12 Details

  • Manufacturer Part Number:

    AH05P-12

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Package Description:

    Module-5

  • ECCN Code:

    EAR99

  • Manufacturer:

    XP Power

  • YTEOL:

    5

  • Analog IC - Other Type:

    DC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CE; UL; CURUS

  • Control Mode:

    VOLTAGE-MODE

  • Input Voltage-Max:

    12 V

  • JESD-30 Code:

    R-XXMA-P5

  • Length:

    23.37 mm

  • Number of Functions:

    1

  • Number of Outputs:

    1

  • Number of Terminals:

    5

  • Operating Temperature-Max:

    75 °C

  • Operating Temperature-Min:

    -25 °C

  • Output Current-Max:

    0.003 A

  • Output Voltage-Max:

    500 V

  • Package Body Material:

    UNSPECIFIED

  • Package Code:

    XMA

  • Package Shape:

    RECTANGULAR

  • Package Style:

    MICROELECTRONIC ASSEMBLY

  • Protections:

    SHORT CIRCUIT

  • Ripple Voltage (Main Out):

    0.0024745 Vrms

  • Seated Height-Max:

    6.86 mm

  • Surface Mount:

    NO

  • Technology:

    HYBRID

  • Temperature Grade:

    COMMERCIAL EXTENDED

  • Terminal Form:

    PIN/PEG

  • Terminal Position:

    UNSPECIFIED

  • Total Power Output-Max:

    1.5 W

  • Trim/Adjustable Output:

    NO

  • Warm-up Time:

    3600 s

  • Width:

    11.43 mm

AH05P-12 Frequently Asked Questions (FAQs)

  • XP Power recommends a PCB layout with a large copper area for heat dissipation, and a thermal management system with a heat sink and thermal interface material to keep the junction temperature below 125°C.
  • To ensure EMC, XP Power recommends following the guidelines in the datasheet for input and output filtering, and using a metal enclosure with proper shielding and grounding to minimize electromagnetic interference.
  • The derating curve for the AH05P-12 can be obtained from XP Power's application notes or by contacting their technical support team. Generally, the output power should be derated by 2.5% per °C above 50°C to ensure reliable operation.
  • Yes, the AH05P-12 can be used in a redundant or parallel configuration, but XP Power recommends consulting their application notes and technical support team to ensure proper implementation and to discuss any specific requirements or limitations.
  • The MTBF of the AH05P-12 is typically in the range of 1-2 million hours, depending on the operating conditions and environment. Contact XP Power's technical support team for more information or to request a reliability report.

Trust Checks

This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

AH05P-12 Overview

Use the download button to access the AH05P-12 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like AH05P, or try a keyword search, such as Power Supply Modules

Parts related to AH05P-12

Showing 0 results