Part Image

ICM-20649 - TDK

Description: IMUs - Inertial Measurement Units Wide-Range 6-Axis MEMS MotionTracking Device for Sports and High Impact Applications

Download ICM-20649 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
ICM-20649 - TDK PCB footprint - Quad Flat No-Lead - Quad Flat No-Lead - 24
click to zoom
3D Models
ICM-20649 - TDK  - 3D model - Quad Flat No-Lead - 24
click to zoom

ICM-20649 Details

  • Manufacturer Part Number:

    ICM-20649

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Obsolete

  • Manufacturer:

    TDK Corporation

  • YTEOL:

    0

  • Body Breadth:

    3 mm

  • Body Height:

    0.88 mm

  • Body Length or Diameter:

    3 mm

  • Mounting Feature:

    SURFACE MOUNT

  • Number of Terminals:

    24

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -40 °C

  • Output:

    OPEN-DRAIN

  • Output Range:

    0.18-1.62V

  • Output Type:

    DIGITAL VOLTAGE

  • Package Body Material:

    PLASTIC/EPOXY

  • Package Equivalence Code:

    LCC24,.13SQ,16

  • Package Shape/Style:

    SQUARE

  • Sensors/Transducers Type:

    ACCELEROMETER/GYROSCOPE

  • Supply Voltage-Max:

    3.6 V

  • Supply Voltage-Min:

    1.71 V

  • Surface Mount:

    YES

  • Technology:

    CMOS

ICM-20649 Frequently Asked Questions (FAQs)

  • The recommended power-on sequence is to power up the VDDIO pin first, followed by the VDD pin. This ensures that the internal voltage regulators are powered up correctly.
  • To configure the ICM-20649 for low-power mode, set the LP_MODE bit in the POWER_CTL register to '1'. This reduces the current consumption of the device.
  • The ICM-20649 can measure accelerations up to ±30g, but the maximum range can be adjusted by setting the FS_SEL bits in the ACCEL_CONFIG register.
  • Calibration involves setting the offset and scale factors for each axis. This can be done by taking measurements at multiple orientations and temperatures, and then calculating the offset and scale factors using the provided equations in the datasheet.
  • The SELF_TEST bit is used to enable a self-test mode, which checks the internal signal paths and analog-to-digital converters for proper operation. This can be used for diagnostic purposes during manufacturing or in-field testing.

Trust Checks

This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

ICM-20649 Overview

Use the download button to access the ICM-20649 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like ICM-2, or try a keyword search, such as Other Sensors/Transducers

About TDK

TDK-Lambda is a global supplier of power supplies and related products. It is a subsidiary of TDK Corporation, a leading electronics company based in Japan. TDK-Lambda specializes in designing and manufacturing a wide range of AC-DC power supplies, DC-DC converters, programmable power supplies, and EMC/EMI filters for various industries and applications.

Parts related to ICM-20649