Part Image

MPXV4006GC7U - NXP

Description: Pressure Sensor, Gauge, 0 kPa, 6 kPa, 4.75 V, 5.25 V, SOP

Download MPXV4006GC7U Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
MPXV4006GC7U - NXP PCB footprint - Other - Other - SOT1863-1
click to zoom

MPXV4006GC7U Details

  • Manufacturer Part Number:

    MPXV4006GC7U

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • Package Description:

    SOP-8

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.01

  • Factory Lead Time:

    52 Weeks

  • Manufacturer:

    NXP Semiconductors

  • YTEOL:

    5

  • Accuracy-Max (%):

    5%

  • Additional Feature:

    TEMPERATURE COMPENSATED, SIGNAL CONDITION

  • Body Breadth:

    10.66 mm

  • Body Height:

    12.95 mm

  • Body Length or Diameter:

    10.66 mm

  • Housing:

    PLASTIC

  • Linearity (%):

    5 %

  • Mounting Feature:

    THROUGH HOLE MOUNT

  • Offset-Nom:

    0.22V

  • Operating Current-Max:

    10 mA

  • Operating Temperature-Max:

    60 °C

  • Operating Temperature-Min:

    10 °C

  • Output Range:

    0.26-4.86V

  • Output Type:

    ANALOG VOLTAGE

  • Package Shape/Style:

    SQUARE

  • Packing Method:

    TUBE

  • Port Type:

    STRAIGHT

  • Pressure Range-Max:

    0.87 Psi

  • Pressure Sensing Mode:

    GAGE

  • Sensors/Transducers Type:

    PRESSURE SENSOR,PIEZORESISTIVE

  • Supply Voltage-Max:

    5.25 V

  • Supply Voltage-Min:

    4.75 V

  • Surface Mount:

    NO

  • Termination Type:

    SOLDER

MPXV4006GC7U Frequently Asked Questions (FAQs)

  • NXP provides a recommended PCB layout and land pattern in the MPXV4006GC7U application note (AN1926). It's essential to follow this layout to ensure proper sensor operation and minimize noise.
  • Calibration involves adjusting the sensor's output to match the desired pressure range. NXP provides a calibration procedure in the MPXV4006GC7U datasheet, which involves applying known pressures and measuring the output voltage.
  • To prevent damage, it's recommended to power up the sensor's VCC pin before applying the analog output voltage (VOUT). This ensures that the internal circuitry is properly initialized.
  • To minimize EMI and RFI, use a shielded cable, keep the sensor away from high-frequency sources, and ensure good grounding. Additionally, use a low-pass filter or a ferrite bead on the output line to reduce noise.
  • The MPXV4006GC7U is rated for pressures up to 10 bar (145 psi). Exceeding this pressure may damage the sensor or affect its accuracy.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

MPXV4006GC7U Overview

Use the download button to access the MPXV4006GC7U schematic symbol and PCB footprint.
To find more CAD model downloads similar to this part, try a partial part number search, like MPXV4, or try a keyword search, such as Pressure Sensors

About NXP

NXP Semiconductors is a leading manufacturer of semiconductor devices with a wide range of semiconductor solutions, including microcontrollers, sensors, connectivity solutions, power management ICs, and security solutions. These products are used in a variety of applications such as automotive, industrial automation, smart homes, mobile devices, and more. NXP Semiconductors is one of the world’s largest semiconductor companies and is headquartered in Eindhoven, the Netherlands.

Parts related to MPXV4006GC7U

Showing 0 results

MPXV4006GC7U Alternates

Showing results

Image Part Number Model
Part Image MPXV4006GC7U STMicroelectronics

Piezoresistive Sensor, Gage, 0Psi Min, 0.87Psi Max, 5%, 0.26-4.86V, Square, Through Hole Mount

Part Image MPXV4006GC7U Freescale Semiconductor

Piezoresistive Sensor, Gage, 0Psi Min, 0.87Psi Max, 5%, 0.26-4.86V, Square, Through Hole Mount