Part Image

W172DIP-5 - Schneider Electric

Description: Relay, Reed; 0.25 A; 5 V (Nom.); 125 mW (Nom.); SPDT; 200 Ohms (Nom.); Rhodium

Download W172DIP-5 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
W172DIP-5 - Schneider Electric PCB footprint - Other - Other - DIP-14_2025
click to zoom
3D Models
W172DIP-5 - Schneider Electric  - 3D model - Other - DIP-14_2025
click to zoom

W172DIP-5 Details

  • Manufacturer Part Number:

    W172DIP-5

  • Part Life Cycle Code:

    Obsolete

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.49.00.50

  • Manufacturer:

    Schneider Electric

  • YTEOL:

    0

  • Additional Feature:

    WITH CLAMPING DIODE

  • Body Breadth:

    7.62 mm

  • Body Height:

    6.98 mm

  • Body Length or Diameter:

    19 mm

  • Coil Current(DC)-Max:

    0.025 A

  • Coil Operate Voltage(DC):

    4 V

  • Coil Power:

    125 mW

  • Coil Release Voltage(DC):

    0.5 V

  • Coil Resistance:

    200 Ω

  • Coil Voltage(DC)-Max:

    5 V

  • Coil/Input Supply Type:

    DC

  • Contact (AC) Max Rating R Load:

    .25A@60VAC

  • Contact Current(AC)-Max:

    0.25 A

  • Contact Current(DC)-Max:

    0.5 A

  • Contact (DC) Max Rating R Load:

    .5A@100VDC

  • Contact Voltage(AC)-Max:

    60 V

  • Contact Voltage(DC)-Max:

    100 V

  • Contact/Output Supply Type:

    AC/DC

  • Electrical Life:

    50000000 Cycle(s)

  • Mounting Feature:

    THROUGH HOLE-STRAIGHT MOUNT

  • Operate Time:

    1 ms

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -40 °C

  • Physical Dimension:

    19mm x 7.62mm x 6.98mm

  • Relay Action:

    MOMENTARY

  • Relay Function:

    SPDT

  • Relay Type:

    DRY REED RELAY

  • Release Time:

    1 ms

  • Sealing:

    IP67

  • Surface Mount:

    NO

  • Termination Type:

    SOLDER

W172DIP-5 Frequently Asked Questions (FAQs)

  • The recommended operating temperature range for the W172DIP-5 is -40°C to 85°C (-40°F to 185°F).
  • Yes, the W172DIP-5 is designed to be compatible with other Schneider Electric products, including their PLCs, HMIs, and other automation devices.
  • The maximum switching frequency of the W172DIP-5 is 100 Hz.
  • No, the W172DIP-5 does not have built-in surge protection. However, it is recommended to use external surge protection devices to ensure the reliability of the system.
  • No, the W172DIP-5 is not designed for use in hazardous locations. It is intended for use in general-purpose industrial control applications.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

W172DIP-5 Overview

Use the download button to access the W172DIP-5 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like W172D, or try a keyword search, such as Reed Relays

Parts related to W172DIP-5

Showing 0 results