Schurter recommends a minimum PCB spacing of 2mm between the fuse and other components, and a minimum of 1.5mm between the fuse and the PCB edge. A fuse holder or clip is also recommended to ensure secure mounting and prevent damage.
The 0041.0402 fuse is designed to meet the requirements of IEC 60127-4, which includes vibration and shock testing. However, it's recommended to consult with Schurter's application engineers to ensure the fuse meets the specific requirements of your application.
To determine the correct fuse rating, you need to consider the maximum current, voltage, and power rating of your circuit. Schurter provides a fuse selection guide and recommends consulting with their application engineers to ensure the correct fuse rating is chosen.
The 0041.0402 fuse has a rated operating temperature range of -40°C to 125°C. However, derating may be necessary for temperatures above 85°C. Consult with Schurter's application engineers to determine the suitability of this fuse for your specific high-temperature application.
The 0041.0402 fuse meets the requirements of IEC 60127-4 and is suitable for use in safety-critical applications. However, it's essential to consult with Schurter's application engineers and ensure that the fuse is used in accordance with the relevant safety standards and regulations.
Trust Checks
This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored
0041.0402 Overview
Use the download button to access the 0041.0402 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like 0041.,
or try a keyword search, such as Pushbutton Switches