Part Image

0443003.DRLC - LITTELFUSE

Description: Surface Mount Fuses 280VAC 3A .028ohms 443LC NANO2

Download 0443003.DRLC Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
0443003.DRLC - LITTELFUSE PCB footprint - Other - Other - 443_Series
click to zoom
3D Models
0443003.DRLC - LITTELFUSE  - 3D model - Other - 443_Series
click to zoom

0443003.DRLC Details

  • Manufacturer Part Number:

    0443003.DRLC

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.10.00.40

  • Manufacturer:

    Littelfuse Inc

  • YTEOL:

    6.96

  • Blow Characteristic:

    SLOW

  • Body Breadth:

    3.12 mm

  • Body Height:

    3.12 mm

  • Body Length or Diameter:

    10.1 mm

  • Circuit Protection Type:

    ELECTRIC FUSE

  • Fuse Size:

    NANO

  • JESD-609 Code:

    e4

  • Joule Integral-Nom:

    51 J

  • Mounting Feature:

    SURFACE MOUNT

  • Operating Temperature-Max:

    125 °C

  • Operating Temperature-Min:

    -55 °C

  • Packing Method:

    TR

  • Rated Breaking Capacity:

    50 A

  • Rated Current:

    3 A

  • Rated Voltage(AC):

    280 V

  • Reference Standard:

    CUL; UL

  • Surface Mount:

    YES

  • Terminal Finish:

    Silver (Ag)

  • Terminal Shape:

    WRAPAROUND

  • Trip Time or Delay:

    120 s

0443003.DRLC Frequently Asked Questions (FAQs)

  • The recommended PCB layout for the 0443003.DRLC involves keeping the component away from high-current carrying traces, using a solid ground plane, and minimizing the distance between the fuse and the circuit it's protecting. Additionally, it's recommended to use a fuse clip or holder to ensure secure mounting and prevent movement during operation.
  • The 0443003.DRLC is designed to operate in temperatures up to 125°C, but its performance may degrade at higher temperatures. It's recommended to derate the fuse's current rating by 1.5% per degree Celsius above 85°C to ensure reliable operation. Additionally, the fuse's melting point may be affected by high temperatures, which can impact its ability to clear faults.
  • The 0443003.DRLC is designed to meet the requirements of IEC 60127-1 and UL 248-1, which include vibration and shock testing. However, it's recommended to ensure that the fuse is properly secured to the PCB using a fuse clip or holder, and that the PCB is designed to withstand the expected vibration and shock levels.
  • The 0443003.DRLC is designed to handle inrush currents and high-surge currents, but its performance may be affected by the duration and magnitude of the surge. It's recommended to ensure that the fuse is sized correctly for the application, and that the circuit is designed to limit the surge current to prevent fuse damage or premature aging.
  • The 0443003.DRLC can be used in parallel or series configurations, but it's recommended to ensure that the fuses are identical and that the circuit is designed to ensure equal current sharing. Additionally, the fuse's performance may be affected by the configuration, and it's recommended to consult with a qualified engineer or the manufacturer's application notes for guidance.

Trust Checks

This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

0443003.DRLC Overview

Use the download button to access the 0443003.DRLC schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like 04430, or try a keyword search, such as Electric Fuses

Parts related to 0443003.DRLC