Part Image

0ADAP9120-RE - BelFuse

Description: Fuses with Leads (Through Hole) FUSE, CERAMIC TUBE 12A, 600VAC/600VDC

Download 0ADAP9120-RE Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
0ADAP9120-RE - BelFuse PCB footprint - Other - Other - 32.8*6.76*6.76mm
click to zoom

0ADAP9120-RE Details

  • Manufacturer Part Number:

    0ADAP9120-RE

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.10.00.40

  • Factory Lead Time:

    10 Weeks

  • Manufacturer:

    Bel Fuse

  • YTEOL:

    7.18

  • Blow Characteristic:

    FAST

  • Body Height:

    32.8 mm

  • Body Length or Diameter:

    6.76 mm

  • Circuit Protection Type:

    ELECTRIC FUSE

  • Fuse Size:

    6x32mm

  • Joule Integral-Nom:

    187 J

  • Mounting Feature:

    THROUGH HOLE

  • Operating Temperature-Max:

    105 °C

  • Operating Temperature-Min:

    -50 °C

  • Packing Method:

    BULK

  • Rated Breaking Capacity:

    10000 A

  • Rated Current:

    12 A

  • Rated Voltage(AC):

    600 V

  • Rated Voltage(DC):

    600 V

  • Reference Standard:

    CE; CUL; UKCA; UL

  • Surface Mount:

    NO

  • Terminal Shape:

    PIN WIRE

  • Trip Time or Delay:

    120 s

0ADAP9120-RE Frequently Asked Questions (FAQs)

  • The recommended PCB layout and thermal management for the 0ADAP9120-RE can be found in the Bel Fuse application note AN-105, which provides guidelines for thermal design, PCB layout, and component placement to ensure optimal performance and reliability.
  • The 0ADAP9120-RE is designed to meet various safety and regulatory standards, including UL, EN, and IEC. To ensure compliance, engineers should follow the recommended design guidelines, use the correct input and output capacitors, and perform the necessary safety testing and certification.
  • While the datasheet specifies the recommended input voltage range, the maximum allowable input voltage deviation is typically ±10% of the nominal input voltage. However, it's recommended to consult with Bel Fuse's technical support or application engineers for specific guidance on input voltage tolerance.
  • The 0ADAP9120-RE is rated for operation up to 85°C, but it can be used in higher temperature environments with derating. The derating factors can be found in the datasheet or by consulting with Bel Fuse's technical support. Engineers should also consider the thermal management and cooling strategies to ensure reliable operation.
  • Bel Fuse provides a troubleshooting guide and application notes that cover common issues and their solutions. Engineers can also consult with Bel Fuse's technical support or application engineers for guidance on troubleshooting and debugging.

Trust Checks

This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

0ADAP9120-RE Overview

Use the download button to access the 0ADAP9120-RE schematic symbol and PCB footprint.
To find more CAD model downloads similar to this part, try a partial part number search, like 0ADAP, or try a keyword search, such as Electric Fuses

Parts related to 0ADAP9120-RE

Showing 0 results