Part Image

3-110-066 - SCHURTER

Description: Surface Mount Fuses UAI 1206, 7.5 A, 32 VDC, Time-Lag T, 18 cm Fuse, SMT, 3.2 x 1.6 mm

Download 3-110-066 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
3-110-066 - SCHURTER PCB footprint - Other - Other - 3.2 x 1.6 mm
click to zoom

3-110-066 Details

  • Manufacturer Part Number:

    3-110-066

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Obsolete

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.10.00.40

  • Factory Lead Time:

    22 Weeks, 3 Days

  • Manufacturer:

    Schurter Electronic Components

  • YTEOL:

    0

  • Blow Characteristic:

    TIME LAG

  • Body Breadth:

    1.6 mm

  • Body Height:

    1.1 mm

  • Body Length or Diameter:

    3.2 mm

  • Circuit Protection Type:

    ELECTRIC FUSE

  • Fuse Size:

    1206

  • Joule Integral-Nom:

    11 J

  • Mounting Feature:

    SURFACE MOUNT

  • Operating Temperature-Max:

    140 °C

  • Operating Temperature-Min:

    -40 °C

  • Packing Method:

    TR, 7 INCH

  • Pre-arcing Time-Min:

    1 ms

  • Rated Breaking Capacity:

    100 A

  • Rated Current:

    7.5 A

  • Rated Voltage(DC):

    32 V

  • Reference Standard:

    AEC-Q200; IEC; UL

  • Surface Mount:

    YES

  • Terminal Shape:

    WRAPAROUND

3-110-066 Frequently Asked Questions (FAQs)

  • The recommended torque for the screw terminals of the 3-110-066 is 0.5 Nm to 1.5 Nm, as specified by Schurter.
  • The 3-110-066 is designed specifically for use with 5x20mm fuses. While it may be possible to use it with other types of fuses, it is not recommended and may not meet safety standards.
  • The 3-110-066 is designed to meet the requirements of IEC 60127-6, which includes vibration testing. However, it's recommended to consult with Schurter or a qualified engineer to ensure the fuse holder meets the specific vibration requirements of your application.
  • The 3-110-066 is designed for indoor use and is not rated for outdoor or harsh environments. If you need a fuse holder for outdoor or harsh environments, consider using a fuse holder with a higher IP rating or consult with Schurter for a suitable alternative.
  • The maximum operating temperature of the 3-110-066 is 85°C, as specified by Schurter.

Trust Checks

This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

3-110-066 Overview

Use the download button to access the 3-110-066 schematic symbol and PCB footprint.
To find more CAD model downloads similar to this part, try a partial part number search, like 3-110, or try a keyword search, such as Electric Fuses

Parts related to 3-110-066

Showing 0 results