Part Image

32.21.7.012.2000 - FINDER

Description: Finder SPDT Non-Latching Relay PCB Mount, 12V dc Coil, 6 A

Download 32.21.7.012.2000 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
32.21.7.012.2000 - FINDER PCB footprint - Other - Other - 32.21.7.012.2000-1
click to zoom
3D Models
32.21.7.012.2000 - FINDER  - 3D model - Other - 32.21.7.012.2000-1
click to zoom

32.21.7.012.2000 Details

  • Manufacturer Part Number:

    32.21.7.012.2000

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Obsolete

  • ECCN Code:

    EAR99

  • Manufacturer:

    FINDER SpA

  • YTEOL:

    0

  • Body Breadth:

    10 mm

  • Body Height:

    10.7 mm

  • Body Length or Diameter:

    20 mm

  • Coil Operate Voltage(DC):

    9.4 V

  • Coil Power:

    200 mW

  • Coil Resistance:

    720 Ω

  • Coil Voltage(DC)-Max:

    18 V

  • Coil Voltage-Nom:

    12 V

  • Coil/Input Supply Type:

    DC

  • Contact (AC) Max Power Rating R Load:

    1500VA@400VAC

  • Contact (AC) Max Rating R Load:

    15A@400VAC

  • Contact Current(AC)-Max:

    15 A

  • Contact Voltage(AC)-Max:

    400 V

  • Contact/Output Supply Type:

    AC/DC

  • Electrical Life:

    100000 Cycle(s)

  • End Contact Material:

    SILVER CADMIUM OXIDE

  • Input Switching Control Type:

    Random

  • Number of Terminals:

    5

  • Operate Time:

    6 ms

  • Physical Dimension:

    20mm x 10mm x 10.7mm

  • Reference Standard:

    UL; VDE

  • Relay Action:

    MBB

  • Relay Form:

    1 FORM C

  • Relay Function:

    SPDT

  • Release Time:

    4 ms

  • Terminal Length:

    0.003500127000254001 inch

  • Termination Type:

    SOLDER

32.21.7.012.2000 Frequently Asked Questions (FAQs)

  • The maximum switching frequency of the relay is 20 operations per minute.
  • No, the relay is designed for low-voltage applications up to 250V AC/30V DC. For high-voltage applications, a different relay model should be used.
  • No, the relay is not designed for use in hazardous locations. It is intended for general-purpose applications only.
  • The operating temperature range of the relay is -40°C to 85°C (-40°F to 185°F).
  • Yes, the relay is compatible with PLC systems and can be controlled using a PLC output.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

32.21.7.012.2000 Overview

Use the download button to access the 32.21.7.012.2000 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like 32.21, or try a keyword search, such as Other Relays

Parts related to 32.21.7.012.2000

Showing 0 results