Part Image

44268 - MYRRA

Description: MYRRA - 44268 - PCB Transformer, EI 48 x 16.8, Encapsulated Safety Isolating, 230V, 15V, 10 VA, 50Hz / 60Hz

Download 44268 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
44268 - MYRRA PCB footprint - Other - Other - 44268-3
click to zoom
3D Models
44268 - MYRRA  - 3D model - Other - 44268-3
click to zoom

44268 Details

  • Manufacturer Part Number:

    44268

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Contact Manufacturer

  • Reach Compliance Code:

    Unknown

  • ECCN Code:

    EAR99

  • HTS Code:

    8504.31.40.35

  • Manufacturer:

    Myrra

  • Approvals:

    EN; UL

  • Center Tap Feature 1:

    NO

  • Center Tap Feature 2:

    NO

  • Height:

    34.75 mm

  • Length:

    50.5 mm

  • Mounting Feature:

    THROUGH HOLE MOUNTED

  • Number of Secondary Winding:

    1

  • Operating Temperature-Max:

    50 °C

  • Output Current 1:

    0.667 A

  • Output Voltage 1:

    15 V

  • Primary Rating:

    SINGLE 230V

  • Surface Mount:

    NO

  • Transformer Type:

    POWER TRANSFORMER

  • VA Rating:

    10 VA

  • Width:

    42.5 mm

44268 Frequently Asked Questions (FAQs)

  • Myrra recommends a 2-layer PCB with a solid ground plane on the bottom layer and a thermal relief pattern around the device's thermal pad to ensure efficient heat dissipation.
  • Myrra suggests using a secure mounting method, such as screwing or adhesive bonding, and ensuring the PCB is properly secured to the system's chassis to minimize mechanical stress on the device.
  • Although not explicitly stated in the datasheet, Myrra recommends limiting voltage transients on the input pins to ±10% of the rated voltage to prevent damage or malfunction.
  • Yes, the 44268 can be paralleled to increase output current, but Myrra recommends using a current-sharing scheme, such as a dedicated current-sensing resistor, to ensure balanced current distribution and prevent uneven stress on the devices.
  • The typical start-up time for the 44268 is around 10-15 ms, although this can vary depending on the specific application and input voltage conditions.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

44268 Overview

Use the download button to access the 44268 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search or try a keyword search, such as Power/Mains Transformers

Parts related to 44268

Showing 0 results