Part Image

ATDR10 - Mersen

Description: Fuse Class CC Slow Blow Acting 10A 600V Holder Cartridge 10.4 X 38.1mm Fiberglass CSA/UL

Download ATDR10 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
ATDR10 - Mersen  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

ATDR10 Details

  • Manufacturer Part Number:

    ATDR10

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • Manufacturer:

    Mersen Electrical Power

  • YTEOL:

    7.13

  • Additional Feature:

    RATED BREAKING CAPACITY AT 300 VDC: 100000 A

  • Blow Characteristic:

    TIME DELAY

  • Body Height:

    38.1 mm

  • Body Length or Diameter:

    10.4 mm

  • Circuit Protection Type:

    ELECTRIC FUSE

  • Mounting Feature:

    INLINE/HOLDER

  • Rated Breaking Capacity:

    200000 A

  • Rated Current:

    10 A

  • Rated Voltage(AC):

    600 V

  • Rated Voltage(DC):

    300 V

  • Reference Standard:

    CSA; UL

  • Surface Mount:

    NO

  • Terminal Shape:

    END CAP

ATDR10 Frequently Asked Questions (FAQs)

  • The recommended torque for the ATDR10's terminals is 1.5 Nm (13.4 lb-in) for the screw terminals and 2.5 Nm (22.1 lb-in) for the busbar connections.
  • Yes, the ATDR10 is designed to withstand high-vibration environments. It meets the vibration requirements of IEC 60068-2-6, which includes sinusoidal vibration testing at 10-2000 Hz, 10g peak acceleration.
  • The ATDR10 is designed to withstand overvoltage conditions up to 1.5 times the rated voltage for a maximum of 1 minute. It also has a built-in overvoltage protection feature that disconnects the output in case of a sustained overvoltage condition.
  • Yes, the ATDR10 is designed to meet the requirements of hazardous locations, including Class I, Division 2, Groups A, B, C, and D, and Zone 2, Group IIC.
  • The ATDR10 requires minimal maintenance. It is recommended to inspect the device every 6 months to ensure that the terminals are clean and free of corrosion, and to verify that the device is operating within the specified temperature range.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable