Part Image

BMI323 - BOSCH

Description: 3.0 SHUTTLE BOARD DEV KIT BMI323

Download BMI323 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
BMI323 - BOSCH PCB footprint - Other - Other - BMI323-2
click to zoom
3D Models
BMI323 - BOSCH  - 3D model - Other - BMI323-2
click to zoom

BMI323 Details

  • Manufacturer Part Number:

    BMI323

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Manufacturer:

    Bosch Sensortec

  • YTEOL:

    3

  • Accuracy-Max (%):

    2%

  • Body Breadth:

    2.5 mm

  • Body Height:

    0.7 mm

  • Body Length or Diameter:

    3 mm

  • Mounting Feature:

    SURFACE MOUNT

  • Number of Terminals:

    14

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -40 °C

  • Output Range:

    0.24-0.96V

  • Output Type:

    DIGITAL VOLTAGE

  • Package Equivalence Code:

    LCC14,.1X.12,20

  • Package Shape/Style:

    RECTANGULAR

  • Sensors/Transducers Type:

    ACCELEROMETER/GYROSCOPE

  • Supply Voltage-Max:

    3.63 V

  • Supply Voltage-Min:

    1.71 V

  • Surface Mount:

    YES

BMI323 Frequently Asked Questions (FAQs)

  • The recommended PCB layout for the BMI323 involves placing the sensor near the edge of the PCB, with the X-axis and Y-axis aligned with the PCB edges. This helps to minimize interference and ensure accurate measurements.
  • The BMI323 does not require calibration in the classical sense. However, it's recommended to perform a self-test function to ensure the sensor is functioning correctly. The self-test function is described in the datasheet.
  • The BMI323 can operate in a temperature range of -40°C to 85°C. However, the sensor's accuracy and performance may degrade at extreme temperatures.
  • The BMI323 is designed for use in atmospheric pressure environments. Using it in a vacuum or high-altitude environment may affect its performance and accuracy. Consult with Bosch Sensortec for custom solutions.
  • To minimize EMI, use a shielded cable, keep the sensor away from high-frequency sources, and ensure good grounding. Additionally, use a low-pass filter to reduce high-frequency noise.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

BMI323 Overview

Use the download button to access the BMI323 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like BMI32, or try a keyword search, such as Other Sensors/Transducers