Part Image

CC3-2403SF-E - TDK Lambda

Description: DC-DC Converters, On-board type, Output: 2.64W, 3.3V, Isolated type, Option: DIP type

Download CC3-2403SF-E Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
CC3-2403SF-E - TDK Lambda PCB footprint - Other - Other - CC31205SFE
click to zoom
3D Models
CC3-2403SF-E - TDK Lambda  - 3D model - Other - CC31205SFE
click to zoom

CC3-2403SF-E Details

  • Manufacturer Part Number:

    CC3-2403SF-E

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • Package Description:

    DIP-7

  • Similar Group:

    CV0210491387

  • ECCN Code:

    EAR99

  • Manufacturer:

    TDK-Lambda Corporation

  • Analog IC - Other Type:

    DC-DC REGULATED POWER SUPPLY MODULE

  • Input Voltage-Max:

    36 V

  • Input Voltage-Min:

    18 V

  • Input Voltage-Nom:

    24 V

  • JESD-30 Code:

    R-MDMA-T7

  • Length:

    22.86 mm

  • Number of Functions:

    1

  • Number of Outputs:

    1

  • Number of Terminals:

    7

  • Operating Temperature-Max:

    50 °C

  • Operating Temperature-Min:

    -40 °C

  • Output Current-Max:

    0.8 A

  • Output Voltage-Max:

    3.6 V

  • Output Voltage-Min:

    3.15 V

  • Output Voltage-Nom:

    3.3 V

  • Package Body Material:

    METAL

  • Package Code:

    DIP

  • Package Equivalence Code:

    DIP7/8,1.4,200

  • Package Shape:

    RECTANGULAR

  • Package Style:

    MICROELECTRONIC ASSEMBLY

  • Qualification Status:

    Not Qualified

  • Surface Mount:

    NO

  • Technology:

    HYBRID

  • Temperature Grade:

    OTHER

  • Terminal Form:

    THROUGH-HOLE

  • Terminal Pitch:

    5.08 mm

  • Terminal Position:

    DUAL

  • Total Power Output-Max:

    3 W

  • Trim/Adjustable Output:

    YES

  • Width:

    16.6 mm

CC3-2403SF-E Frequently Asked Questions (FAQs)

  • The recommended input fuse rating is 2A slow-blow type, but it's recommended to consult the datasheet and application notes for specific requirements.
  • The CC3-2403SF-E is rated for operation up to 71°C, but derating is required above 50°C. Consult the datasheet for thermal derating curves and ensure proper cooling and airflow.
  • Follow the recommended layout and grounding guidelines in the datasheet and application notes. Ensure proper shielding, filtering, and decoupling to minimize EMI and RFI.
  • The maximum cable length for the output connectors is 30cm (12 inches) to minimize voltage drop and ensure reliable operation.
  • Yes, but it's recommended to consult the datasheet and application notes for specific guidelines on paralleling units, including synchronization and current sharing.

Trust Checks

This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

CC3-2403SF-E Overview

Use the download button to access the CC3-2403SF-E schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like CC3-2, or try a keyword search, such as Power Supply Modules

Parts related to CC3-2403SF-E

Showing 0 results