XP Power recommends a PCB layout with a large copper area connected to the module's thermal pad to dissipate heat efficiently. A minimum of 1 oz copper thickness is recommended, and the copper area should be at least 1 inch x 1 inch in size.
Yes, the ISH0505A-H is designed to withstand high-vibration environments. It meets the IEC 60068-2-6 standard for vibration resistance, which includes sinusoidal vibration testing at 10-2000 Hz, 2G amplitude, and random vibration testing at 10-2000 Hz, 4G RMS.
To ensure EMC, XP Power recommends following proper PCB layout and design guidelines, such as keeping sensitive analog circuits away from the DC-DC converter, using proper grounding and shielding, and following the recommended input and output filtering.
The maximum allowable capacitance on the output of the ISH0505A-H is 2200 uF. Exceeding this value may affect the module's stability and performance.
Yes, the ISH0505A-H is designed to operate up to 5000 meters (16,400 feet) above sea level. However, the module's power rating may need to be de-rated at higher altitudes due to the lower air pressure and oxygen levels.
Trust Checks
This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored
ISH0505A-H Overview
Use the download button to access the ISH0505A-H schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like ISH05,
or try a keyword search, such as Power Supply Modules