LS200-12 Details

  • Manufacturer Part Number:

    LS200-12

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • ECCN Code:

    EAR99

  • Manufacturer:

    TDK-Lambda Corporation

  • Additional Feature:

    REMOTE SHUTDOWN

  • Analog IC - Other Type:

    AC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CE; CSA; UL

  • Efficiency (Main Output):

    79%

  • Input Voltage-Max:

    264 V

  • Input Voltage-Min:

    85 V

  • Length:

    199 mm

  • Operating Temperature-Max:

    70 °C

  • Operating Temperature-Min:

    -25 °C

  • Output Current-Max:

    16.7 A

  • Output Voltage-Nom:

    12 V

  • Protections:

    OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL

  • Ripple Voltage (Main Out):

    0.04242 Vrms

  • Width:

    98 mm

LS200-12 Frequently Asked Questions (FAQs)

  • The LS200-12 can operate in a temperature range of -20°C to +70°C, with a derating of 2.5% per °C above 50°C.
  • To ensure reliability in high-vibration environments, it is recommended to secure the LS200-12 using the provided mounting holes and to follow the recommended torque values. Additionally, consider using vibration-dampening materials or mounting the power supply on a vibration-isolated platform.
  • Yes, the LS200-12 can be used in a redundant configuration to achieve high availability and reliability. However, it is essential to follow the recommended redundancy configuration guidelines and to ensure that the power supplies are properly synchronized and monitored.
  • The recommended input fuse rating for the LS200-12 is 2A slow-blow or 1A fast-acting fuse, depending on the specific application and installation requirements.
  • The LS200-12 provides a range of monitoring and control signals, including a DC OK signal, a power fail signal, and a remote on/off control input. These signals can be connected to a remote monitoring system or a building management system (BMS) to monitor the status of the power supply.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

LS200-12 Overview

Use the download button to access the LS200-12 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like LS200, or try a keyword search, such as Power Supply Modules

Parts related to LS200-12

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview