MBCM270T450M270A00 Details

  • Manufacturer Part Number:

    MBCM270T450M270A00

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Part Package Code:

    DMA

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.01

  • Factory Lead Time:

    28 Weeks

  • Manufacturer:

    Vicor Corporation

  • Analog IC - Other Type:

    DC-DC REGULATED POWER SUPPLY MODULE

  • Qualification Status:

    Not Qualified

MBCM270T450M270A00 Frequently Asked Questions (FAQs)

  • The module requires a heat sink with a thermal resistance of ≤ 1.5°C/W to ensure proper thermal performance. A minimum clearance of 0.5 mm around the module is recommended for airflow and heat dissipation.
  • The input voltage range for MBCM270T450M270A00 is 36-75 Vdc. Ensure that the input voltage is within this range to prevent damage to the module. Use voltage regulation or filtering if necessary to maintain a stable input voltage.
  • Follow Vicor's recommended PCB layout and routing guidelines to minimize noise, EMI, and thermal issues. Keep high-frequency signals away from sensitive analog signals, and use a solid ground plane to reduce noise and improve thermal performance.
  • The output voltage can be trimmed using the TRIM pin. Connect a resistor between the TRIM pin and the output voltage sense point to adjust the output voltage. Refer to the datasheet for specific trimming resistor values and calculations.
  • The module is designed to meet CISPR 22 Class B and EN 55022 Class B EMI standards. Ensure proper PCB layout, grounding, and shielding to minimize EMI and EMC issues. Use EMI filters or shielding if necessary to meet specific application requirements.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

MBCM270T450M270A00 Overview

Use the download button to access the MBCM270T450M270A00 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like MBCM2, or try a keyword search, such as Other Signal Circuits

Parts related to MBCM270T450M270A00

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview