Bourns provides a recommended PCB layout and land pattern in their application note AN164, which can be found on their website. It's essential to follow these guidelines to ensure proper mounting and to minimize thermal resistance.
To handle the high current rating, ensure that the PCB traces and vias are designed to handle the maximum current. Use thick copper traces (at least 2 oz) and multiple vias to reduce resistance and thermal stress. Also, consider using a heat sink or thermal pad to dissipate heat.
Although the datasheet specifies an operating temperature range of -40°C to 125°C, it's essential to note that the device's performance and reliability may degrade above 100°C. For optimal performance, it's recommended to operate the device within a temperature range of -20°C to 85°C.
To ensure the magnetic shield is effective, make sure to follow proper mounting and handling procedures. The shield should be soldered to the PCB, and the device should be handled in a way that minimizes mechanical stress, which can compromise the shield's integrity.
Store the MH1005-121Y in a dry, cool place, away from direct sunlight and moisture. Handle the device by the body, avoiding touching the leads or magnetic shield. Use anti-static packaging and follow ESD handling procedures to prevent damage.
Trust Checks
This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored
MH1005-121Y Overview
Use the download button to access the MH1005-121Y schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like MH100,
or try a keyword search, such as Data Line Filters