Part Image

Q50-5 - XP POWER

Description: XP Power Q50-5 DC to High Voltage DC Converter 0 → 5 V dc 100µA 5kV dc

Download Q50-5 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
Q50-5 - XP POWER PCB footprint - Other - Other - Q50-5-2
click to zoom
3D Models
Q50-5 - XP POWER  - 3D model - Other - Q50-5-2
click to zoom

Q50-5 Details

  • Manufacturer Part Number:

    Q50-5

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Similar Group:

    CV0217451648

  • ECCN Code:

    EAR99

  • Manufacturer:

    XP Power

  • YTEOL:

    5

  • Analog IC - Other Type:

    DC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CE; CSA; EN; IEC; TUV; UL

  • Input Voltage-Max:

    5 V

  • Input Voltage-Min:

    0.7 V

  • JESD-30 Code:

    S-XDMA-P4

  • Length:

    12.7 mm

  • Number of Functions:

    1

  • Number of Outputs:

    1

  • Number of Terminals:

    4

  • Operating Temperature-Max:

    60 °C

  • Operating Temperature-Min:

    -25 °C

  • Output Current-Max:

    0.0001 A

  • Output Voltage-Max:

    5000 V

  • Package Body Material:

    UNSPECIFIED

  • Package Code:

    DMA

  • Package Shape:

    SQUARE

  • Package Style:

    MICROELECTRONIC ASSEMBLY

  • Protections:

    SHORT CIRCUIT

  • Qualification Status:

    Not Qualified

  • Seated Height-Max:

    13.21 mm

  • Surface Mount:

    NO

  • Technology:

    HYBRID

  • Terminal Form:

    PIN/PEG

  • Terminal Position:

    DUAL

  • Total Power Output-Max:

    0.5 W

  • Trim/Adjustable Output:

    YES

  • Width:

    12.7 mm

Q50-5 Frequently Asked Questions (FAQs)

  • The Q50-5 can operate from -20°C to +70°C, with derating above 50°C.
  • Yes, the Q50-5 is certified for use in Class I, Division 2 hazardous locations, making it suitable for use in industrial environments.
  • The MTBF of the Q50-5 is approximately 550,000 hours, calculated according to MIL-HDBK-217F.
  • Yes, the Q50-5 can be used in a redundant configuration, with features such as parallel operation and current sharing, to ensure high availability and reliability.
  • The hold-up time of the Q50-5 is typically 10ms, ensuring that the output voltage remains stable during brief input power interruptions.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

Q50-5 Overview

Use the download button to access the Q50-5 schematic symbol, PCB footprint, and 3D model.