Part Image

RAC20-24SK/277 - RECOM Power

Description: 20W AC/DC-Converter 'POWERLINE' 2"x1" 3kV reg

Download RAC20-24SK/277 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
RAC20-24SK/277 - RECOM Power  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

RAC20-24SK/277 Details

  • Manufacturer Part Number:

    RAC20-24SK/277

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Reach Compliance Code:

    Compliant

  • Country Of Origin:

    Mainland China, Taiwan

  • ECCN Code:

    EAR99

  • Manufacturer:

    RECOM Power GmbH

  • Analog IC - Other Type:

    AC-DC REGULATED POWER SUPPLY MODULE

  • Peak Reflow Temperature (Cel):

    NOT SPECIFIED

  • Time@Peak Reflow Temperature-Max (s):

    NOT SPECIFIED

RAC20-24SK/277 Frequently Asked Questions (FAQs)

  • RECOM recommends a PCB layout with a large copper area for heat dissipation, and a thermal management system with a heat sink and thermal interface material to keep the junction temperature below 100°C.
  • The RAC20-24SK/277 is certified to IEC/EN/UL 62368-1 and IEC/EN 60335-1, but it's essential to ensure that the entire system meets the required safety certifications. Consult with RECOM's application notes and safety guidelines for specific requirements.
  • The maximum allowable capacitance for the output filter capacitor is 220uF. Exceeding this value may affect the stability of the converter and lead to oscillations or reduced performance.
  • Yes, the RAC20-24SK/277 can be used in a redundant or parallel configuration, but it's essential to follow RECOM's application notes and guidelines for proper implementation to ensure reliable operation and avoid potential issues.
  • RECOM recommends a fuse rating of 2A to 5A, depending on the specific application and input voltage. A slow-blow fuse type is recommended to ensure reliable operation and protection against overcurrent conditions.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

RAC20-24SK/277 Overview

Use the download button to access the RAC20-24SK/277 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like RAC20, or try a keyword search, such as Power Supply Modules

Parts related to RAC20-24SK/277

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview