Part Image

SF-2410FA2000W-2 - Bourns

Description: Surface Mount Fuses 20 AMP 65V FAST ACTING

Download SF-2410FA2000W-2 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
SF-2410FA2000W-2 - Bourns PCB footprint - Fuses Chip - Fuses Chip - SF-2410FA2000W-2*-*-
click to zoom
3D Models
SF-2410FA2000W-2 - Bourns  - 3D model - Fuses Chip - SF-2410FA2000W-2*-*-
click to zoom

SF-2410FA2000W-2 Details

  • Manufacturer Part Number:

    SF-2410FA2000W-2

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.10.00.40

  • Factory Lead Time:

    18 Weeks

  • Manufacturer:

    Bourns Inc

  • YTEOL:

    8

  • Blow Characteristic:

    FAST

  • Body Breadth:

    2.49 mm

  • Body Height:

    2.16 mm

  • Body Length or Diameter:

    6.1 mm

  • Circuit Protection Type:

    ELECTRIC FUSE

  • Fuse Size:

    2410

  • Joule Integral-Nom:

    126 J

  • Mounting Feature:

    SURFACE MOUNT

  • Operating Temperature-Max:

    125 °C

  • Operating Temperature-Min:

    -55 °C

  • Packing Method:

    TR, 7 INCH

  • Pre-arcing Time-Min:

    10 ms

  • Rated Breaking Capacity:

    100 A

  • Rated Current:

    20 A

  • Rated Voltage(DC):

    65 V

  • Reference Standard:

    AEC-Q200; UL

  • Surface Mount:

    YES

  • Terminal Shape:

    WRAPAROUND

SF-2410FA2000W-2 Frequently Asked Questions (FAQs)

  • Bourns recommends a symmetrical PCB layout with a solid ground plane, and keeping the input and output traces as short as possible to minimize EMI and noise. A 4-layer PCB with a dedicated ground plane is also recommended.
  • Ensure good airflow around the device, and consider using a heat sink if the device is expected to operate in high-temperature environments. Also, follow the recommended derating curves for temperature and power dissipation.
  • The maximum allowable voltage imbalance is ±10% of the nominal input voltage. Exceeding this limit may affect the device's performance, reliability, and lifespan.
  • Yes, but it's essential to follow Bourns' guidelines for parallel and redundant configurations, including using identical devices, ensuring proper synchronization, and implementing adequate overcurrent protection.
  • Start by checking the input voltage, output load, and ambient temperature. Verify that the device is properly soldered and that the PCB layout meets the recommended guidelines. Use an oscilloscope to monitor the input and output waveforms, and consult Bourns' application notes and technical support resources for further assistance.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

SF-2410FA2000W-2 Overview

Use the download button to access the SF-2410FA2000W-2 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like SF-24, or try a keyword search, such as Electric Fuses

Parts related to SF-2410FA2000W-2

Showing 0 results