The recommended power-up sequence is to apply VCC first, followed by a delay of at least 15 ms, and then apply the clock signal. This ensures proper initialization of the device.
The SHT10's output is open-drain, which means it can only sink current, not source it. To use the output, you need to add a pull-up resistor to a voltage source, such as VCC.
The maximum cable length for the SHT10's digital interface is approximately 10 meters (33 feet). Exceeding this length may result in signal degradation or errors.
The SHT10 outputs a digital value representing the humidity measurement. To convert this value to a relative humidity (RH) value, use the formula: RH = -42.22 + 241.4 * (output value / 2^14).
The SHT10's temperature accuracy is specified as ±0.4°C (±0.72°F) at 25°C (77°F). This accuracy is valid for the entire operating temperature range of -40°C to 123.8°C (-40°F to 250°F).