Part Image

TCK-140 - Traco Power

Description: Common Mode Chokes / Filters EMC Chokes for DC/DC Converters

Download TCK-140 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
TCK-140 - Traco Power PCB footprint - Other - Other - TCK-140-2
click to zoom
3D Models
TCK-140 - Traco Power  - 3D model - Other - TCK-140-2
click to zoom

TCK-140 Details

  • Manufacturer Part Number:

    TCK-140

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8504.50.80.00

  • Manufacturer:

    Traco Power

  • YTEOL:

    6.79

  • DC Resistance-Max:

    0.055 Ω

  • Filter Type:

    DATA LINE FILTER

  • Height:

    4.5 mm

  • Inductance:

    137.5 µH

  • Length:

    6.5 mm

  • Mounting Type:

    SURFACE MOUNT

  • Number of Functions:

    2

  • Number of Terminals:

    4

  • Operating Temperature-Max:

    105 °C

  • Operating Temperature-Min:

    -40 °C

  • Rated Current:

    0.64 A

  • Rated Voltage:

    500 V

  • Width:

    6 mm

TCK-140 Frequently Asked Questions (FAQs)

  • The TCK-140 can drive a maximum capacitive load of 10uF. Exceeding this value may cause instability or oscillation.
  • The TCK-140 meets various safety certifications such as UL60950-1, EN60950-1, and IEC60950-1. Ensure that your application meets the required safety standards by following the guidelines provided in the datasheet and relevant safety certifications.
  • To minimize EMI, place the TCK-140 as close as possible to the load, and use a solid ground plane. Keep the input and output traces separate and use a shielded cable for the input. Additionally, use a common-mode choke or ferrite bead on the input to reduce EMI.
  • The TCK-140 is rated for operation up to 80°C ambient temperature. However, derating is required for temperatures above 60°C. Consult the datasheet for derating curves and ensure that your application meets the required temperature specifications.
  • To troubleshoot issues with the TCK-140, check the input voltage, output load, and ambient temperature. Ensure that the device is properly soldered and that the layout meets the recommended guidelines. Use an oscilloscope to check for output voltage stability and consult the datasheet for troubleshooting guidelines.

Trust Checks

This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

TCK-140 Overview

Use the download button to access the TCK-140 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like TCK-1, or try a keyword search, such as Data Line Filters

Parts related to TCK-140

Showing 0 results