Part Image

ZPSA60-15 - TDK Lambda

Description: AC-DC Power Supplies, Open frame, Output: 60W, 15V, Convection

Download ZPSA60-15 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
ZPSA60-15 - TDK Lambda  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

ZPSA60-15 Details

  • Manufacturer Part Number:

    ZPSA60-15

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • ECCN Code:

    EAR99

  • Manufacturer:

    TDK-Lambda Corporation

  • Analog IC - Other Type:

    AC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CE, CSA, UL

  • Efficiency (Main Output):

    85%

  • Input Voltage-Max:

    264 V

  • Input Voltage-Min:

    90 V

  • Length:

    101.6 mm

  • Line Regulation-Max:

    0.5%

  • Load Regulation-Max:

    1%

  • Operating Temperature-Max:

    70 °C

  • Output Current-Max:

    4 A

  • Output Voltage-Nom:

    15 V

  • Peak Reflow Temperature (Cel):

    NOT SPECIFIED

  • Protections:

    OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE

  • Time@Peak Reflow Temperature-Max (s):

    NOT SPECIFIED

  • Total Power Output-Max:

    60 W

  • Width:

    50.8 mm

ZPSA60-15 Frequently Asked Questions (FAQs)

  • The maximum operating temperature range for the ZPSA60-15 is -20°C to +71°C, with derating above 50°C.
  • Yes, the ZPSA60-15 can be used up to 3,000 meters (10,000 feet) above sea level without derating.
  • The hold-up time for the ZPSA60-15 is typically 10ms, which means the output voltage will remain within regulation for at least 10ms after the input power is removed.
  • Yes, the ZPSA60-15 can be paralleled for higher power applications, but it requires a special parallel operation circuit and consultation with TDK-Lambda's technical support team.
  • The MTBF for the ZPSA60-15 is typically >500,000 hours at 25°C, calculated according to MIL-HDBK-217F.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

ZPSA60-15 Overview

Use the download button to access the ZPSA60-15 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like ZPSA6, or try a keyword search, such as Power Supply Modules

Parts related to ZPSA60-15

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview