Part Image

MAX3001EEUP+ - Analog Devices

Description: MAX3001EEUP+, Octal Voltage Level Translator, LVCMOS, LVTTL, 3-State 1.65 → 5.5 V 20-Pin TSSOP

Download MAX3001EEUP+ Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
MAX3001EEUP+ - Analog Devices PCB footprint - Small Outline Packages - Small Outline Packages - 20 TSSOP
click to zoom
3D Models
MAX3001EEUP+ - Analog Devices  - 3D model - Small Outline Packages - 20 TSSOP
click to zoom

MAX3001EEUP+ Details

  • Manufacturer Part Number:

    MAX3001EEUP+

  • Brand Name:

    Analog Devices Inc

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Part Package Code:

    20-TSSOP_4.4-4.4_MM

  • Package Description:

    TSSOP-20

  • Pin Count:

    20

  • Manufacturer Package Code:

    20-TSSOP_4.4-4.4_MM

  • Country Of Origin:

    Japan, Mainland China, Malaysia, Philippines, Singapore, South Korea, Taiwan, Thailand, USA

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.01

  • Date Of Intro:

    2002-11-29

  • Manufacturer:

    Analog Devices Inc

  • YTEOL:

    8.5

  • Delay-Max:

    50 ns

  • Interface IC Type:

    VOLTAGE LEVEL TRANSLATOR

  • JESD-30 Code:

    R-PDSO-G20

  • JESD-609 Code:

    e3

  • Length:

    6.5 mm

  • Moisture Sensitivity Level:

    1

  • Number of Bits:

    8

  • Number of Functions:

    1

  • Number of Terminals:

    20

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -40 °C

  • Output Latch or Register:

    NONE

  • Output Polarity:

    TRUE

  • Package Body Material:

    PLASTIC/EPOXY

  • Package Code:

    TSSOP

  • Package Equivalence Code:

    TSSOP20,.25

  • Package Shape:

    RECTANGULAR

  • Package Style:

    SMALL OUTLINE, THIN PROFILE, SHRINK PITCH

  • Peak Reflow Temperature (Cel):

    260

  • Qualification Status:

    Not Qualified

  • Seated Height-Max:

    1.1 mm

  • Supply Current-Max:

    0.05 mA

  • Supply Voltage-Max:

    5.5 V

  • Supply Voltage-Min:

    1.2 V

  • Supply Voltage-Nom:

    1.2 V

  • Supply Voltage1-Max:

    5.5 V

  • Supply Voltage1-Min:

    1.65 V

  • Supply Voltage1-Nom:

    1.65 V

  • Surface Mount:

    YES

  • Technology:

    BICMOS

  • Temperature Grade:

    INDUSTRIAL

  • Terminal Finish:

    Matte Tin (Sn) - annealed

  • Terminal Form:

    GULL WING

  • Terminal Pitch:

    0.65 mm

  • Terminal Position:

    DUAL

  • Time@Peak Reflow Temperature-Max (s):

    30

  • Width:

    4.4 mm

MAX3001EEUP+ Frequently Asked Questions (FAQs)

  • A good PCB layout for the MAX3001EEUP+ involves keeping the analog and digital grounds separate, using a solid ground plane, and minimizing the distance between the device and the ECG electrodes. A 4-layer PCB with a dedicated analog layer is recommended. Additionally, it's essential to follow the layout guidelines provided in the datasheet and application notes.
  • The MAX3001EEUP+ requires calibration to ensure accurate ECG measurements. Calibration involves setting the gain and offset of the device using the CAL_IN pin. A calibration procedure is provided in the datasheet, which involves applying a known voltage to the CAL_IN pin and adjusting the gain and offset registers accordingly. It's essential to follow the calibration procedure carefully to ensure accurate measurements.
  • The MAX3001EEUP+ requires a well-decoupled power supply to ensure accurate ECG measurements. A recommended decoupling scheme involves using a 10uF ceramic capacitor and a 100nF ceramic capacitor in parallel, placed close to the device's power pins. Additionally, a 1uF capacitor can be used to decouple the analog and digital power supplies.
  • EMI can be a significant issue when using the MAX3001EEUP+, as it can affect the accuracy of ECG measurements. To minimize EMI, it's essential to use a shielded cable for the ECG electrodes, keep the device away from sources of EMI, and use a metal enclosure for the device. Additionally, using a common-mode choke and EMI filters can help to reduce EMI.
  • The recommended clock frequency for the MAX3001EEUP+ is between 1MHz and 2MHz. A higher clock frequency can result in increased noise and decreased accuracy, while a lower clock frequency can result in decreased sampling rates and increased power consumption.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

MAX3001EEUP+ Overview

Use the download button to access the MAX3001EEUP+ schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like MAX30, or try a keyword search, such as Other Interface ICs

About Analog Devices

Analog Devices Inc. is a global leader in the design and manufacturing of analog, mixed-signal, and digital signal processing integrated circuits and software solutions for the industrial, automotive, healthcare, communications industries. Analog Devices serves a diverse range of markets including industrial, automotive, healthcare, energy, aerospace, defense, and consumer electronics industries. Analog Devices’ product portfolio includes a wide range of ICs, modules, and subsystems.

Parts related to MAX3001EEUP+

Showing 0 results