Vicor recommends a 4-layer PCB with a solid ground plane, and thermal vias under the module to dissipate heat. A minimum of 2 oz copper thickness is recommended. Additionally, a thermal interface material (TIM) should be used between the module and the heat sink.
To ensure reliable start-up and shutdown, Vicor recommends a soft-start circuit to limit inrush current, and a voltage supervisor to monitor the input voltage and ensure the converter is enabled only when the input voltage is within the specified range.
The maximum allowed capacitance on the output of the 37052-601 is 2200uF. Exceeding this value may cause instability or oscillation in the converter.
Yes, the 37052-601 can be used in a parallel configuration to increase output power. However, Vicor recommends using a dedicated parallel bus to connect the modules, and ensuring that the modules are synchronized to prevent oscillation.
Vicor recommends a fuse rating of 5A to 10A, depending on the input voltage and current requirements of the application. The fuse should be sized to protect the converter from overcurrent conditions.
Trust Checks
This model has been verified by system checks.
System Verified
Sponsored
37052-601 Overview
Use the download button to access the 37052-601 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like 37052,
or try a keyword search, such as Fixed Inductors