The recommended power-on sequence is to first apply VDDIO, then VDD, and finally configure the device. This ensures proper initialization and prevents unwanted behavior.
The self-test feature is used to verify the accelerometer's functionality. To use it, set the ST bit in the COMMAND register (0x7E). The device will then perform a self-test, and the result can be read from the SELF_TEST register (0x6F).
The interrupt pins (INT1 and INT2) can be configured to trigger on specific events, such as data ready, FIFO full, or sensor thresholds. This allows the microcontroller to be notified of important events without continuous polling.
To configure FIFO mode, set the FIFO_EN bit in the FIFO_CONFIG_1 register (0x46). Then, configure the FIFO mode (stream or trigger) and the watermark level using the FIFO_CONFIG_1 and FIFO_CONFIG_2 registers (0x46-0x47).
The BMA280 operates within a temperature range of -40°C to 85°C. However, the device's accuracy and performance may degrade at extreme temperatures.