Part Image

CXE240D5 - CRYDOM

Description: Solid State Relay 15mA 32V DC-IN 5A 280V AC-OUT 4-Pin SIP

Download CXE240D5 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
CXE240D5 - CRYDOM PCB footprint - Other - Other - CXE240D5-2
click to zoom
3D Models
CXE240D5 - CRYDOM  - 3D model - Other - CXE240D5-2
click to zoom

CXE240D5 Details

  • Manufacturer Part Number:

    CXE240D5

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • HTS Code:

    8541.40.95.00

  • Manufacturer:

    Crydom Inc

  • Additional Feature:

    UL RECOGNIZED, VDE APPROVED, ZERO VOLTAGE CROSSING

  • Configuration:

    SINGLE

  • Control Current:

    0.015 A

  • Control Voltage:

    15 V

  • Input Type:

    DC

  • Isolation Voltage-Max:

    4000 V

  • JESD-609 Code:

    e3

  • Number of Elements:

    1

  • On-State Current-Max:

    5 A

  • Operating Temperature-Max:

    80 °C

  • Operating Temperature-Min:

    -30 °C

  • Optoelectronic Device Type:

    TRIGGER OUTPUT SSR

  • Output Circuit Type:

    Triac

  • Overall Height:

    25 mm

  • Overall Length:

    43 mm

  • Terminal Finish:

    Tin (Sn) - with Nickel (Ni) barrier

CXE240D5 Frequently Asked Questions (FAQs)

  • A thermal pad on the bottom of the device should be connected to a large copper area on the PCB to dissipate heat. The copper area should be at least 1 inch x 1 inch in size and connected to a ground plane to ensure good heat dissipation.
  • Use a secure mounting method such as screwing or clipping the device to the PCB or chassis. Ensure the PCB is securely fastened to the chassis to prevent movement and vibration.
  • The maximum allowable voltage drop across the CXE240D5 is 2.5V. Exceeding this voltage drop may cause the device to overheat or malfunction.
  • Yes, but ensure the device is properly sealed and conformal coated to prevent moisture ingress. The device is rated for operation in humid environments, but proper precautions should be taken to prevent moisture-related failures.
  • A fuse rating of 5A to 10A is recommended for overcurrent protection, depending on the specific application and maximum expected current.

Trust Checks

This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

CXE240D5 Overview

Use the download button to access the CXE240D5 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like CXE24, or try a keyword search, such as Solid State Relays

Parts related to CXE240D5

Showing 0 results

CXE240D5 Alternates

Showing results

Image Part Number Model
Part Image CXE240D5 Sensata Circuit Breakers

Trigger Output SSR, 1-Channel, 4000V Isolation