ECM40UT31 Details

  • Manufacturer Part Number:

    ECM40UT31

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • Manufacturer:

    XP Power

  • YTEOL:

    7

  • Analog IC - Other Type:

    AC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CSA, EN, UL

  • Efficiency (Main Output):

    85%

  • Input Voltage-Max:

    264 V

  • Input Voltage-Min:

    90 V

  • Input Voltage-Nom:

    115 V

  • Length:

    101.6 mm

  • Line Regulation-Max:

    0.5%

  • Load Regulation-Max:

    3%

  • Number of Functions:

    1

  • Number of Outputs:

    3

  • Operating Temperature-Max:

    70 °C

  • Output Current-Max:

    0.6 A

  • Output Voltage-Nom:

    5 V

  • Protections:

    OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE

  • Total Power Output-Max:

    40 W

  • Width:

    50.8 mm

ECM40UT31 Frequently Asked Questions (FAQs)

  • XP Power recommends a PCB layout with a large copper area for heat dissipation, and a minimum of 2oz copper thickness. A thermal via array under the module can also improve heat transfer.
  • To ensure reliable start-up, XP Power recommends a soft-start circuit to limit inrush current, and a sufficient input capacitance to stabilize the input voltage. A minimum input voltage of 1.5 times the nominal input voltage is also recommended.
  • The maximum allowable capacitance on the output of the ECM40UT31 is 47μF. Exceeding this value may affect the stability of the output voltage.
  • The ECM40UT31 is rated for operation up to 80°C ambient temperature. However, derating the output power is recommended for temperatures above 60°C to ensure reliable operation.
  • XP Power recommends using a TVS (Transient Voltage Suppressor) diode or a voltage clamp circuit to protect the ECM40UT31 from input voltage transients and spikes.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

ECM40UT31 Overview

Use the download button to access the ECM40UT31 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like ECM40, or try a keyword search, such as Power Supply Modules

Parts related to ECM40UT31

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview