Part Image

ECS-100A-100 - ECS

Description: Standard Clock Oscillators OSC XO 10.000MHZ TTL PC PIN 10MHz - TTL 5V +/-100ppm 0 C 70 C 30mA Through Hole 0.821" L x 0.520" W (20.86mm x 13.20mm) 0.200" (5.08mm) 14-DIP, 4 Leads (Full Size, Metal Can)

Download ECS-100A-100 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
ECS-100A-100 - ECS PCB footprint - Other - Other - ECS-100A-100-1
click to zoom
3D Models
ECS-100A-100 - ECS  - 3D model - Other - ECS-100A-100-1
click to zoom

ECS-100A-100 Details

  • Manufacturer Part Number:

    ECS-100A-100

  • Pbfree Code:

    Yes

  • Part Life Cycle Code:

    Obsolete

  • Package Description:

    RESISTANCE WELDED, METAL PACKAGE-14/4

  • ECCN Code:

    EAR99

  • Factory Lead Time:

    18 Weeks

  • Manufacturer:

    ECS International Inc

  • YTEOL:

    0

  • Fall Time-Max:

    10 ns

  • Frequency Adjustment-Mechanical:

    NO

  • Frequency Stability:

    100%

  • Mounting Feature:

    THROUGH HOLE MOUNT

  • Number of Terminals:

    14

  • Operating Frequency-Nom:

    10 MHz

  • Operating Temperature-Max:

    70 °C

  • Oscillator Type:

    TTL

  • Output Load:

    10 TTL

  • Physical Dimension:

    20.86mm x 13.2mm x 5.08mm

  • Rise Time-Max:

    10 ns

  • Supply Voltage-Max:

    5.25 V

  • Supply Voltage-Min:

    4.75 V

  • Supply Voltage-Nom:

    5 V

  • Surface Mount:

    NO

  • Symmetry-Max:

    60/40 %

ECS-100A-100 Frequently Asked Questions (FAQs)

  • ECS International Inc recommends a 4-layer PCB with a dedicated ground plane and thermal vias to ensure efficient heat dissipation. A minimum of 2 oz copper thickness is recommended for the power traces. Additionally, a thermal pad on the bottom of the device should be connected to a heat sink or a thermal management system.
  • To ensure EMC, ECS International Inc recommends following proper PCB design and layout guidelines, using shielding and filtering components, and implementing a robust grounding scheme. Additionally, the device should be placed in a metal enclosure with proper shielding and filtering to minimize electromagnetic interference (EMI).
  • The ECS-100A-100 is rated for operation from -40°C to 85°C. However, it's recommended to derate the device's performance and power handling at temperatures above 70°C to ensure reliable operation and prevent thermal runaway.
  • Yes, the ECS-100A-100 is designed to withstand vibrations up to 10 G RMS from 10 Hz to 2 kHz. However, it's recommended to follow proper mounting and screwing procedures to ensure the device is securely fastened to the PCB or chassis.
  • ECS International Inc recommends storing the ECS-100A-100 in a dry, cool place away from direct sunlight and moisture. The device should be handled with anti-static wrist straps and mats to prevent electrostatic discharge (ESD) damage.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

ECS-100A-100 Overview

Use the download button to access the ECS-100A-100 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like ECS-1, or try a keyword search, such as XO

Parts related to ECS-100A-100

Showing 0 results