Part Image

FN2090B-6-06 - Schaffner

Description: Schaffner FN2090 Series 6A 250 V ac 0 → 400Hz Chassis Mount Power Line Filter, with Tab Terminals

Download FN2090B-6-06 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
FN2090B-6-06 - Schaffner  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

FN2090B-6-06 Details

  • Manufacturer Part Number:

    FN2090B-6-06

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • Package Description:

    ROHS COMPLIANT PACKAGE

  • Country Of Origin:

    Thailand

  • Manufacturer:

    Schaffner

  • YTEOL:

    8

  • Additional Feature:

    INDUCTANCE 8 MILLIHENRY; MEDICAL VERSION

  • Approvals:

    UL; CSA; ENEC-14

  • Filter Type:

    SINGLE PHASE EMI FILTER

  • Height:

    30.3 mm

  • High Pot:

    2500 V

  • Leakage Current-Max:

    0.002 mA

  • Length:

    64.8 mm

  • Mounting Type:

    PANEL MOUNT

  • Operating Frequency:

    50/60Hz Hz

  • Operating Temperature-Max:

    100 °C

  • Operating Temperature-Min:

    -25 °C

  • Physical Dimension:

    L64.8XB49.8XH30.3 (mm)/L2.551XB1.961XH1.193 (inch)

  • Rated Current:

    6.7 A

  • Rated Voltage:

    250 V

  • Width:

    49.8 mm

FN2090B-6-06 Frequently Asked Questions (FAQs)

  • Schaffner recommends a minimum of 2mm spacing between the filter and other components, and a solid ground plane underneath the filter to minimize electromagnetic interference. A good PCB layout should also ensure that the input and output traces are separated and not routed near each other.
  • The FN2090B-6-06 is rated for operation up to 80°C, but its performance may degrade at higher temperatures. It's recommended to derate the filter's current rating by 1.5% per degree Celsius above 60°C to ensure reliable operation.
  • While the FN2090B-6-06 meets general industrial standards, it may not meet the specific requirements of medical or aerospace applications. Engineers should consult Schaffner's application notes and relevant industry standards (e.g., IEC 60601-1 for medical devices) to ensure the filter meets the necessary safety and performance requirements.
  • The FN2090B-6-06 is designed to withstand voltage surges up to 2.5kV, but it's not a substitute for dedicated surge protection devices. Engineers should consider adding additional surge protection components to ensure the filter and downstream equipment are protected from voltage spikes and transients.
  • Yes, the FN2090B-6-06 can be used in parallel or series configurations to achieve higher current ratings or improved filtering performance. However, engineers should ensure that the filters are properly matched and configured to avoid resonance or other performance issues.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

FN2090B-6-06 Overview

Use the download button to access the FN2090B-6-06 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like FN209, or try a keyword search, such as Mains Filters

Parts related to FN2090B-6-06

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview