Part Image

HE1WPR/03 - Altech

Description: Barrier Terminal Blocks EUROSTRIP 3 POLE 8MM SP 20A 300V

Download HE1WPR/03 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
HE1WPR/03 - Altech  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

HE1WPR/03 Details

  • Manufacturer Part Number:

    HE1WPR/03

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.90.40.00

  • Manufacturer:

    Altech Corporation

  • YTEOL:

    7

  • Terminal and Terminal Block Type:

    POWER DISTRIBUTION BLOCK

HE1WPR/03 Frequently Asked Questions (FAQs)

  • Altech recommends a 4-layer PCB with a dedicated ground plane and thermal vias to dissipate heat. A minimum of 2 oz copper thickness is recommended for the power traces. Additionally, a thermal pad on the bottom of the device should be connected to a heat sink or a thermal management system.
  • To ensure EMC, Altech recommends following the guidelines in the IEC 61000-4 series of standards. This includes using a metal enclosure, proper cable shielding, and filtering on the input and output lines. Additionally, the device should be placed at least 10 mm away from other components to minimize electromagnetic interference.
  • Altech provides a derating curve in the application note AN-001, which shows the recommended power derating at high temperatures. The curve indicates that the device can operate up to 85°C with a maximum power derating of 20%.
  • Yes, the HE1WPR/03 can be used in a redundant or parallel configuration to increase power availability and reliability. However, Altech recommends consulting with their application engineers to ensure proper design and implementation of the redundant or parallel system.
  • Altech recommends using a pi-filter (L-C-L) configuration on the input and output lines to minimize electromagnetic interference and ensure electromagnetic compatibility. The filter components should be selected based on the specific application requirements and operating frequency.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

HE1WPR/03 Overview

Use the download button to access the HE1WPR/03 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like HE1WP, or try a keyword search, such as Terminals and Terminal Blocks

Parts related to HE1WPR/03

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview