The IPA70R450P7SXKSA1 can operate from -40°C to 150°C, with a junction temperature (Tj) of up to 175°C.
The device has a thermal pad on the bottom that should be connected to a heat sink or a thermal interface material (TIM) to ensure proper heat dissipation. A minimum thermal resistance of 1.5 K/W is recommended.
A 2-layer or 4-layer PCB is recommended, with a solid ground plane and a separate power plane. The device's thermal pad should be connected to the heat sink or TIM, and the PCB should be designed to minimize thermal resistance.
The IPA70R450P7SXKSA1 requires a specific power sequencing order: VCC should be powered up first, followed by VGS. The device should not be operated with VGS greater than VCC.
The IPA70R450P7SXKSA1 has built-in ESD protection, but it is still recommended to follow standard ESD handling procedures when handling the device. A human body model (HBM) of 2 kV and a charged device model (CDM) of 1 kV are recommended.
Trust Checks
This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored
IPA70R450P7SXKSA1 Overview
Use the download button to access the IPA70R450P7SXKSA1 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like IPA70,
or try a keyword search, such as Power Field-Effect Transistors