Part Image

ISL3171EIUZ - Renesas Electronics

Description: The Renesas ISL317xE are ±15kV IEC61000 ESD protected, 3. 3V powered single transceivers that meet both the RS-485 and RS-422 standards for balanced communication. These devices have very low bus currents (+125µA/-100µA), so they present a true “1/8 unit load” to the RS-485 bus. This allows up to 256 transceivers on the network without violating the RS-485 specification's 32 unit load maximum, and without using repeaters. For example, in a remote utility meter reading system, individual meter readings are r

Download ISL3171EIUZ Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
ISL3171EIUZ - Renesas Electronics PCB footprint - Small Outline Packages - Small Outline Packages - M8.118
click to zoom
3D Models
ISL3171EIUZ - Renesas Electronics  - 3D model - Small Outline Packages - M8.118
click to zoom

ISL3171EIUZ Details

  • Manufacturer Part Number:

    ISL3171EIUZ

  • Brand Name:

    Renesas

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Part Package Code:

    MSOP

  • Package Description:

    MSOP-8

  • Pin Count:

    8

  • Manufacturer Package Code:

    M8.118

  • Country Of Origin:

    Malaysia, Thailand

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.60

  • Factory Lead Time:

    12 Weeks

  • Manufacturer:

    Renesas Electronics Corporation

  • YTEOL:

    7

  • Differential Output:

    YES

  • Driver Number of Bits:

    1

  • High Level Input Current-Max:

    0.000002 A

  • Input Characteristics:

    DIFFERENTIAL SCHMITT TRIGGER

  • Interface IC Type:

    LINE TRANSCEIVER

  • Interface Standard:

    EIA-422; EIA-485

  • JESD-30 Code:

    S-PDSO-G8

  • JESD-609 Code:

    e3

  • Length:

    3 mm

  • Moisture Sensitivity Level:

    2

  • Number of Functions:

    1

  • Number of Terminals:

    8

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -40 °C

  • Out Swing-Min:

    1.5 V

  • Output Low Current-Max:

    0.004 A

  • Output Polarity:

    COMPLEMENTARY

  • Package Body Material:

    PLASTIC/EPOXY

  • Package Code:

    TSSOP

  • Package Shape:

    SQUARE

  • Package Style:

    SMALL OUTLINE, THIN PROFILE, SHRINK PITCH

  • Peak Reflow Temperature (Cel):

    260

  • Receive Delay-Max:

    120 ns

  • Receiver Number of Bits:

    1

  • Seated Height-Max:

    1.1 mm

  • Supply Current-Max:

    0.8 mA

  • Supply Voltage-Max:

    3.6 V

  • Supply Voltage-Min:

    3 V

  • Supply Voltage-Nom:

    3.3 V

  • Supply Voltage1-Max:

    3.6 V

  • Supply Voltage1-Min:

    3 V

  • Supply Voltage1-Nom:

    3.3 V

  • Surface Mount:

    YES

  • Technology:

    BICMOS

  • Temperature Grade:

    INDUSTRIAL

  • Terminal Finish:

    Matte Tin (Sn) - annealed

  • Terminal Form:

    GULL WING

  • Terminal Pitch:

    0.65 mm

  • Terminal Position:

    DUAL

  • Time@Peak Reflow Temperature-Max (s):

    30

  • Transmit Delay-Max:

    1500 ns

  • Width:

    3 mm

ISL3171EIUZ Frequently Asked Questions (FAQs)

  • Renesas provides a recommended PCB layout in the ISL3171EIUZ evaluation board user manual, which includes guidelines for component placement, routing, and thermal management to ensure optimal performance and minimize noise.
  • To ensure reliable operation in high-temperature environments, it is recommended to follow the thermal management guidelines in the datasheet, including using a heat sink, thermal interface material, and ensuring good airflow. Additionally, consider using a thermistor or temperature sensor to monitor the device temperature and implement thermal shutdown or throttling if necessary.
  • The maximum cable length for the RS-485 bus depends on the data rate, cable characteristics, and noise environment. As a general guideline, Renesas recommends a maximum cable length of 4000 feet (1219 meters) at a data rate of 10 Mbps. However, it is recommended to perform signal integrity analysis and testing to determine the maximum cable length for a specific application.
  • To implement fault tolerance and error detection in an RS-485 design, consider using techniques such as checksums, cyclic redundancy checks (CRCs), and error-correcting codes. Additionally, implement fault detection mechanisms such as bus fault detection, receiver timeout, and transmitter timeout. The ISL3171EIUZ also provides a fault detection pin that can be used to detect bus faults and errors.
  • The ISL3171EIUZ has built-in ESD protection diodes on the RS-485 pins, which can withstand electrostatic discharges up to ±15 kV. Additionally, the device is designed to prevent latch-up, a condition where a device becomes stuck in a high-current state, by using a latch-up prevention circuit. However, it is still recommended to follow proper ESD handling and prevention procedures during device handling and PCB assembly.

Trust Checks

This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

ISL3171EIUZ Overview

Use the download button to access the ISL3171EIUZ schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like ISL31, or try a keyword search, such as Line Driver or Receivers

Parts related to ISL3171EIUZ

Showing 0 results