Part Image

LY2-AC220/240 - OMRON Electronics

Description: General Purpose Relays DPDT PLUG-IN/SOLDER

Download LY2-AC220/240 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
LY2-AC220/240 - OMRON Electronics  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

LY2-AC220/240 Details

  • Manufacturer Part Number:

    LY2-AC220/240

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Reach Compliance Code:

    Compliant

  • Country Of Origin:

    Indonesia

  • ECCN Code:

    EAR99

  • HTS Code:

    8536.41.00.20

  • Factory Lead Time:

    6 Weeks

  • Manufacturer:

    OMRON Electronic Components

  • Additional Feature:

    COIL OPERATE VOLTAGE(AC): 192 V, COIL RELEASE VOLTAGE(AC): 72 V

  • Body Breadth:

    21.59 mm

  • Body Height:

    36.06 mm

  • Body Length or Diameter:

    27.94 mm

  • Coil Current(AC)-Max:

    0.005 A

  • Coil Power:

    1200 mW

  • Coil Voltage(AC)-Max:

    240 V

  • Coil/Input Supply Type:

    AC

  • Contact (AC) Max Rating R Load:

    10A@110VAC

  • Contact Current(AC)-Max:

    10 A

  • Contact Current(DC)-Max:

    10 A

  • Contact (DC) Max Rating R Load:

    10A@24VDC

  • Contact Voltage(AC)-Max:

    110 V

  • Contact Voltage(DC)-Max:

    24 V

  • Contact/Output Supply Type:

    AC/DC

  • Mounting Feature:

    PANEL MOUNT

  • Operate Time:

    25 ms

  • Operating Temperature-Max:

    55 °C

  • Operating Temperature-Min:

    -25 °C

  • Physical Dimension:

    27.94mm x 21.59mm x 36.06mm

  • Reference Standard:

    CE; CSA; TUV; UL

  • Relay Action:

    MOMENTARY

  • Relay Function:

    DPDT

  • Relay Type:

    POWER/SIGNAL RELAY

  • Release Time:

    25 ms

  • Surface Mount:

    NO

  • Termination Type:

    SOLDER

LY2-AC220/240 Frequently Asked Questions (FAQs)

  • The recommended wiring method is to use a twisted pair cable with a shielded wire to minimize electromagnetic interference (EMI) and ensure reliable communication.
  • No, LY2-AC220/240 is not designed for use in hazardous locations. It is intended for general-purpose industrial control applications only.
  • The maximum cable length for LY2-AC220/240 is 100 meters (328 feet) for a single relay output and 50 meters (164 feet) for multiple relay outputs.
  • Yes, LY2-AC220/240 can be used with a PLC or other control device that has a compatible input/output configuration. However, additional programming and configuration may be required.
  • The operating temperature range for LY2-AC220/240 is -20°C to 55°C (-4°F to 131°F).

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

LY2-AC220/240 Overview

Use the download button to access the LY2-AC220/240 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like LY2-A, or try a keyword search, such as Power/Signal Relays

Parts related to LY2-AC220/240

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview