PM200RG1B065 Details

  • Manufacturer Part Number:

    PM200RG1B065

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.60

  • Manufacturer:

    Mitsubishi Electric

  • YTEOL:

    9.8

  • Additional Feature:

    CONTROL SUPPLY VOLTAGE= 15V

  • Analog IC - Other Type:

    AC SERVO MOTOR CONTROLLER

  • JESD-30 Code:

    R-XXFM-X19

  • Number of Functions:

    1

  • Number of Terminals:

    19

  • Operating Temperature-Max:

    125 °C

  • Operating Temperature-Min:

    -20 °C

  • Output Current-Max:

    300 A

  • Package Body Material:

    UNSPECIFIED

  • Package Code:

    XFM

  • Package Shape:

    RECTANGULAR

  • Package Style:

    FLANGE MOUNT

  • Supply Voltage-Max (Vsup):

    400 V

  • Supply Voltage-Nom (Vsup):

    300 V

  • Surface Mount:

    NO

  • Technology:

    HYBRID

  • Temperature Grade:

    OTHER

  • Terminal Form:

    UNSPECIFIED

  • Terminal Position:

    UNSPECIFIED

PM200RG1B065 Frequently Asked Questions (FAQs)

  • The maximum operating temperature of the PM200RG1B065 is 150°C, but it's recommended to operate it at a maximum of 125°C for reliable operation.
  • Proper thermal management can be achieved by ensuring good heat sink contact, using a suitable thermal interface material, and maintaining a low thermal resistance between the module and heat sink.
  • The recommended gate resistance for the PM200RG1B065 is between 10 ohms and 100 ohms, depending on the specific application and switching frequency.
  • Yes, the PM200RG1B065 can be used in a parallel configuration, but it's essential to ensure that the modules are matched in terms of electrical characteristics and thermal performance to avoid uneven current sharing.
  • The maximum allowable voltage imbalance between the DC link and the AC output is typically ±10% of the nominal voltage, but this may vary depending on the specific application and system design.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

PM200RG1B065 Overview

Use the download button to access the PM200RG1B065 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like PM200, or try a keyword search, such as Motion Control Electronics

Parts related to PM200RG1B065

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview