  • Manufacturer Part Number:

    Q20-5

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • ECCN Code:

    EAR99

  • Manufacturer:

    XP Power

  • YTEOL:

    5

  • Analog IC - Other Type:

    DC-DC REGULATED POWER SUPPLY MODULE

  • Approvals:

    CE, CSA, EN, IEC, TUV, UL

  • Input Voltage-Max:

    5 V

  • Input Voltage-Min:

    0.7 V

  • JESD-30 Code:

    S-XDMA-P4

  • Length:

    12.7 mm

  • Number of Functions:

    1

  • Number of Outputs:

    1

  • Number of Terminals:

    4

  • Operating Temperature-Max:

    70 °C

  • Operating Temperature-Min:

    -25 °C

  • Output Current-Max:

    0.00025 A

  • Output Voltage-Max:

    2000 V

  • Package Body Material:

    UNSPECIFIED

  • Package Code:

    DMA

  • Package Shape:

    SQUARE

  • Package Style:

    MICROELECTRONIC ASSEMBLY

  • Peak Reflow Temperature (Cel):

    NOT SPECIFIED

  • Protections:

    SHORT CIRCUIT

  • Qualification Status:

    Not Qualified

  • Seated Height-Max:

    13.21 mm

  • Surface Mount:

    NO

  • Technology:

    HYBRID

  • Terminal Form:

    PIN/PEG

  • Terminal Position:

    DUAL

  • Time@Peak Reflow Temperature-Max (s):

    NOT SPECIFIED

  • Total Power Output-Max:

    0.5 W

  • Trim/Adjustable Output:

    YES

  • Width:

    12.7 mm

Q20-5 Frequently Asked Questions (FAQs)

  • The maximum operating temperature range for the Q20-5 is -20°C to +70°C, with derating above 50°C.
  • Yes, the Q20-5 is designed to operate in humid environments, with a relative humidity of up to 95% non-condensing.
  • The MTBF of the Q20-5 is approximately 550,000 hours at 25°C, calculated according to MIL-HDBK-217F.
  • Yes, the Q20-5 meets the requirements for medical applications, including EN 60601-1 and IEC 60601-1, and is suitable for use in medical devices.
  • Yes, the Q20-5 is certified for use in Class I, Division 2 hazardous locations, as per UL 1604 and CSA C22.2 No. 213.

Trust Checks

This model has been provided by community users.
Community Provided
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

Q20-5 Overview

Use the download button to access the Q20-5 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search or try a keyword search, such as Other Signal Circuits

Parts related to Q20-5

Showing 0 results