Part Image

RTHN-5010 - TDK Lambda

Description: Power Line EMC Filters, 3-phase/3-line(500V), Rated Current:10A, Wide range high attenuation, Block terminal

Download RTHN-5010 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
3D Models
RTHN-5010 - TDK Lambda  - 3D model
click to zoom
Note! To download footprints and symbols, use the build and request forms below

Build

Launch Build Wizard
Build Wizard not available for this package category!

Request (48 hours)

RTHN-5010 Details

  • Manufacturer Part Number:

    RTHN-5010

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Transferred

  • Manufacturer:

    TDK-Lambda Corporation

  • Approvals:

    UL; EN

  • Filter Type:

    THREE PHASE EMI FILTER

  • Height:

    50 mm

  • Insulation Resistance-Min:

    100 MΩ

  • Leakage Current-Max:

    5 mA

  • Length:

    210 mm

  • Mounting Type:

    PANEL MOUNT

  • Operating Frequency:

    60Hz Hz

  • Operating Temperature-Max:

    85 °C

  • Operating Temperature-Min:

    -25 °C

  • Rated Current:

    10 A

  • Rated Voltage:

    500 V

  • Width:

    95 mm

RTHN-5010 Frequently Asked Questions (FAQs)

  • The recommended input fuse rating is 10A slow-blow type, but it may vary depending on the specific application and environmental conditions. It's recommended to consult with a TDK-Lambda representative or a qualified electrical engineer for specific guidance.
  • Yes, the RTH-5010 can be operated in parallel for higher power output, but it requires a special configuration and synchronization of the units. It's recommended to consult with a TDK-Lambda representative or a qualified electrical engineer for specific guidance and to ensure proper operation.
  • The RTH-5010 is rated for operation up to 3,000 meters (10,000 feet) above sea level. However, derating may be required for higher altitudes. Consult with a TDK-Lambda representative or a qualified electrical engineer for specific guidance.
  • Yes, the RTH-5010 can be used in a redundant configuration for high-reliability applications. However, it requires a special configuration and synchronization of the units. It's recommended to consult with a TDK-Lambda representative or a qualified electrical engineer for specific guidance and to ensure proper operation.
  • The typical MTBF rating for the RTH-5010 is >500,000 hours at 25°C, calculated according to MIL-HDBK-217F. However, this rating may vary depending on the specific application and environmental conditions.

Trust Checks

No trust score is available for this model.
Trust Score Unavailable
Sponsored

RTHN-5010 Overview

Use the download button to access the RTHN-5010 3D model. You can still request or build the schematic symbol and PCB footprint by using the respective build or request forms on this page.
To find more CAD model downloads similar to this part, try a partial part number search, like RTHN-, or try a keyword search, such as Mains Filters

Parts related to RTHN-5010

Showing 0 results

Select Package Category

Package Categories

Datasheet PDF Preview