The recommended PCB footprint for the IXGF30N400 is a standard TO-247 package with a minimum pad size of 5.5mm x 3.5mm and a thermal pad size of 10mm x 10mm.
Yes, the IXGF30N400 is suitable for high-frequency switching applications up to 100 kHz, but it's essential to consider the device's switching losses, thermal performance, and layout to ensure reliable operation.
To ensure proper cooling, provide a sufficient heat sink with a thermal resistance of ≤ 1°C/W, and ensure good thermal contact between the device and the heat sink. Also, consider the airflow and ambient temperature in your design.
The maximum allowed case temperature for the IXGF30N400 is 150°C, but it's recommended to keep the case temperature below 125°C for reliable operation and to prevent thermal runaway.
Yes, you can parallel multiple IXGF30N400 devices to increase current handling, but it's crucial to ensure that the devices are properly matched, and the gate drive and layout are designed to minimize current imbalance and oscillations.
Trust Checks
This model has been provided by an expert contributor.
Expert Contribution
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored
IXGF30N400 Overview
Use the download button to access the IXGF30N400 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search, like IXGF3,
or try a keyword search, such as IGBTs