Part Image

SA01 - Apex Microtechnology

Description: 20A, 100V PWM Amplifier with Programmable Current Limit, Voltage supply operation – 16V to 100V, High output current - 20A continuous, 30A PEAK, Power delivered to load - 2,000W.

Download SA01 Model
Schematic
symbols
Schematic symbol is unavailable for download
PCB
footprints
PCB footprint is unavailable for download
3D
models
3D model is unavailable for download
PCB Footprints
SA01 - Apex Microtechnology PCB footprint - Other - Other - SA01
click to zoom
3D Models
SA01 - Apex Microtechnology  - 3D model - Other - SA01
click to zoom

SA01 Details

  • Manufacturer Part Number:

    SA01

  • Pbfree Code:

    Yes

  • Rohs Code:

    Yes

  • Part Life Cycle Code:

    Active

  • Part Package Code:

    DFM

  • Package Description:

    HERMETIC SEALED, POWER PACK-10

  • Pin Count:

    10

  • Country Of Origin:

    USA

  • ECCN Code:

    EAR99

  • HTS Code:

    8542.39.00.60

  • Manufacturer:

    Apex Microtechnology Inc

  • YTEOL:

    8

  • Analog IC - Other Type:

    3-PHASE BRUSHLESS DC MOTOR CONTROLLER

  • JESD-30 Code:

    R-MDFM-P10

  • Number of Functions:

    1

  • Number of Terminals:

    10

  • Operating Temperature-Max:

    125 °C

  • Operating Temperature-Min:

    -55 °C

  • Output Current-Max:

    30 A

  • Package Body Material:

    METAL

  • Package Code:

    DFM

  • Package Shape:

    RECTANGULAR

  • Package Style:

    FLANGE MOUNT

  • Qualification Status:

    Not Qualified

  • Supply Voltage-Max (Vsup):

    100 V

  • Supply Voltage-Min (Vsup):

    16 V

  • Supply Voltage-Nom (Vsup):

    50 V

  • Surface Mount:

    NO

  • Temperature Grade:

    MILITARY

  • Terminal Finish:

    Nickel (Ni)

  • Terminal Form:

    PIN/PEG

  • Terminal Position:

    DUAL

SA01 Frequently Asked Questions (FAQs)

  • Apex Microtechnology recommends a 4-layer PCB with a solid ground plane, and a separate analog and digital power plane. The SA01 should be placed near the analog power plane, and the input and output capacitors should be placed as close as possible to the device.
  • To ensure stability, Apex recommends using a minimum output capacitance of 10uF, and a maximum output capacitance of 100uF. Additionally, the input and output capacitors should be placed as close as possible to the device, and the PCB layout should be designed to minimize parasitic inductance and capacitance.
  • The maximum safe operating area (SOA) for the SA01 is defined by the maximum voltage and current ratings. The device can operate safely up to 100V and 10A, but the user should ensure that the device is operated within the recommended operating conditions to prevent damage or degradation.
  • Apex recommends using external overvoltage protection (OVP) and overcurrent protection (OCP) circuits to protect the SA01 from damage. The OVP circuit should be designed to clamp the input voltage to a safe level, and the OCP circuit should be designed to limit the output current to a safe level.
  • The thermal derating curve for the SA01 is not explicitly stated in the datasheet, but Apex recommends derating the device by 1.5% per degree Celsius above 25°C. This means that the device's power rating should be reduced by 1.5% for every degree above 25°C to prevent overheating and ensure reliable operation.

Trust Checks

This model has been built in collaboration with the manufacturer.
Manufacturer Collaborated
This model has been verified by system checks.
System Verified
This model has been reviewed by community users.
Community Approved
Sponsored

SA01 Overview

Use the download button to access the SA01 schematic symbol, PCB footprint, and 3D model.
To find more CAD model downloads similar to this part, try a partial part number search or try a keyword search, such as Silicon Controlled Rectifiers

Parts related to SA01

Showing 0 results

SA01 Alternates

Showing results

Image Part Number Model
Part Image SA01 Cirrus Logic

3-PHASE BRUSHLESS DC MOTOR CONTROLLER, 30A, MDFM10